I used this product to determine the transfection efficiency of my myc-tag-containing construct onto target cells. This antibody gives excellent readings after as little 10mins incubation and has a very low background/non-specific staining

Experimental Design and Results Summary

Applications

Flow Cytometry

Sample

Human T-cells

Primary Incubation

1uL/million cells, 15mins, room temperate

Blocking Agent

None

Secondary Incubation

None

Tertiary Incubation

None

Detection

Flow Cytometry

Results Summary

I have used this product consistently for over 2 years to help determine how efficiently my construct has been transduced into my target cells (human T-cells). In our study we used 9e10-FITC antibody to study CAR T-cells persistence and proliferation. The antibody is efficient and works really well, giving nice separation between positive and negative populations