The overall goal of this study was to phenotype the resident cells across various tissues. The more specific goal was to sort T cell sub types and perform RNA sequencing from the single cell. This product was chosen because the UV excitable fluorophore fit well into our panel.
Flow Cytometry
Rhesus macaque PBMCs
PBMCs were isolated from blood and washed in PBS. Blue Fixable Live/Dead cell dye was added in 1:1000 dilution to approximately 1 million of cells for 15 minutes on ice protected from light.
Add dye before the samples were incubated with block buffer containing FBS
Using live/dead cell dye allowed us to select only for the viable cells and ensure that cells we sorted were worth experimenting with.
Dye needs to be first resuspended in DMSO and should be stored at -20C
Ease of use, bright signal
Dye
This dye works well and I would recommend it to others.
Product Name: LIVE/DEAD Fixable Blue Dead Cell Stain Kit, for UV excitationSupplier Page