I am studying splenic B-cell development and tolerance mechanisms. The goals of my experiment were to phenotype spleens from various genotypes. CD44 BV605 was used to assess B-cell activation using this surface marker. It provided a wide range spectrum of staining.
Flow Cytometry
Splenocytes
20min ice
Fc Block 5min
NA
Flow cytometry
CD44 BV605 stain works well at 1:200 at 1 million cells in 200uL volume.
None
CD44 BV605 is able to separate activated B-cells from non-activated.
This antibody can be used to distinguish activated from non-activated B cells