I used this antibody to confirm the pluripotency state of human embryonic stem cells by flow cytometry.
Flow Cytometry
H9 cell line
1:50, room temperature, 15 minutes
FACS buffer
None
Fluorescence
This antibody produced good signal for embryonic stem cells. As the stem cells differentiated, the SSEA4 staining became weaker.
N/A
Strong and specific signal
I would recommend using this antibody to stain embryonic stem cells as a marker.