Biolegend
PE anti-human FOXP3 Antibody
320108
Info:Supplier Page View Product SpecsView Product
Browse Similar Products: FOXP3 Flow Cytometry Antibodies
This antibody has been used to optimise flow cytometry-based immunophenotyping of whole blood samples. The results have not yet been published. Multi-colour antibody panels were designed to identify a number of lymphocyte populations and tested to ensure appropriate compensation was possible. This antibody was used within a staining panel for T cells to help distinguish Treg cells.
Flow Cytometry
Human whole blood
5uL PE-FoxP3 for 30 minutes at 4oC
FcR blocking reagent, human (Miltenyi Biotec, cat# 130-059-901)
NA
Beckman Coulter Galios, Kaluza software
Clear staining that allowed the distinction of Treg cells. Prior to analysing samples erythrocytes were lysed using 1.5ml 1xPharmLyse (BD, cat#555899) at room temperature for 30 minutes. This antibody fit well into a nine colour panel with no compensation issues.
Clear staining and useful for FACS analysis.
The antibody has only been tested for flow cytometry
Easy to use antibody pack that provided clear and distinct staining of Treg cells.