Flow Cytometers / Flow Cytometry Systems

Flow cytometers are specialized instruments that analyze populations of cells and particles using laser-based fluorescence detection. Particles are suspended in a stream of fluid and flow through a detector in a single file. Individual particles are then analyzed using fluorescent markers, such as conjugated specific antibodies. A cell sorter is a type of cytometer that also isolates and collects desired cell populations for further analysis or for cell culture. Image cytometers, meanwhile use microscopy and fluorescence imaging capabilities for cell analysis. Flow cytometry is widely used in basic and clinical research for techniques such as cell counting, cell characterization, cell-based assays, protein and biomarker detection, microbial analysis, and more.

Browse our catalog of flow cytometers from leading manufacturers and evaluate models by different attributes, such as the number of detection parameters, number of lasers, accommodated laser wavelengths, sample input formats, throughput, and more. Instruments may also come with unique software, which should be user-friendly for flow cytometry novices, and advanced for experienced users to perform sophisticated experimental setups and analyses. Consider whether your laboratory needs a system that permits customization and provides imaging capability, and the degree of resolution your lab requires. Look for features such as automatic start-up, shutdown or cleaning, partially or fully automated processing, and quality customer support and service provided by the manufacturer.

Flow Cytometers / Flow Cytometry Systems

Your search returned 28 Flow Cytometers / Flow Cytometry Systems across 8 suppliers.
Showing 8 of 8 suppliers (28 products total)
  • <<
  • >>
Select up to 5 products from below to compare or request more information.

Sponsored Products

Bio-Rad
ZE5 Cell Analyzer
  • Abs / Exc:
    Up to five spatially separated lasers. Standard options include:
    355 nm, 50 mW
    488 nm, 100 mW
    640 nm, ...
  • Detection:
    Up to five lasers and 30 detectors including seven colors
  • Sample Type:
    Up to 40 5 mL (12 x 75 mm) tube rack, up to 24 1.5- and 2-mL micro-centrifuge tube rack, 96- or 384-...
  • Throughput:
    Inquire
Read More
Citations:
(363)
Figures:
(6)
Miltenyi Biotec
MACSQuant&#174; Tyto&#174; Cell Sorter
  • Abs / Exc:
    405 nm, 488 nm, 638 nm
  • Detection:
    Backscatter detector, Sidescatter detector and eight fluorescence detectors
  • Sample Type:
    Cartridge details: 100 µL–10 mL max loading volume; 5×107 cells/mL max loading cell number
  • Throughput:
    up to 110,000 cells/s
Read More
Citations:
(50)
MACSQuant<sup>&#174;</sup> Analyzer 10 Flow Cytometer
  • Abs / Exc:
    405 nm (violet)
    488 nm (blue)
    640 nm (red)
  • Detection:
    FSC, SSC, 8 fluorescence channels
  • Sample Type:
    1.5/2.0/5.0/15/50 mL tubes or 24/48/96-well plates
  • Throughput:
    Up to 15,000 events per second
Read More
Citations:
(417)
Figures:
(2)
BD Biosciences
BD Accuri&#153; C6 Plus Flow Cytometer
  • Abs / Exc:
    488 nm (Blue), 640 nm (Red)
  • Detection:
    The system is equipped with a blue laser and a red laser, and capable of 6 detection parameters; (...
  • Sample Type:
    Standard 96-well plates (flat, round and v-bottom) Deep-well 96-well plates 48-well plates. Plates ...
  • Throughput:
    Inquire
Read More
Citations:
(398)
Figures:
(2)
BD FACSCelesta&#153; Flow Cytometer
  • Abs / Exc:
    488 nm (Blue), 640 nm (Red), 405 nm (Violet), 561 nm (Yellow/Green), 355 nm (UV)
  • Detection:
    FSC, SSC, up to 12 fluorescence colors
  • Sample Type:
    5 mL (12 x 75 mm) tubes, 96- or 384-well high-throughput sampler option
  • Throughput:
    15 min per microtiter plate in high-throughput mode using a 2-second acquisition; 44 minutes in ...
Read More
Citations:
(351)
Standard BioTools Inc.
CyTOF&reg; XT Next Generation Mass Cytometer
  • Abs / Exc:
    Inquire
  • Detection:
    135 Channels; 75–209 amu (Mass range)
  • Sample Type:
    Single-cell suspension; Sample format: 12 x 5 mL tube positions 1 x 15 mL tube positions
  • Throughput:
    Flow rate: 30 µL/min
Agilent Technologies
NovoCyte Benchtop Flow Cytometer
  • Abs / Exc:
    488 nm, 640 nm, 405 nm
  • Detection:
    Up to 17 parameters
  • Sample Type:
    12 × 75 mm tubes, 1.5 & 2 mL tubes, 24-well and 96-well microtiter plates
Citations:
(1)
NovoCyte Quanteon Flow Cytometer
  • Abs / Exc:
    405 nm, 488 nm, 561 nm, 637 nm
  • Detection:
    25 independent photomultipliers
  • Sample Type:
    12 × 75 mm tubes, 1.5 and 2 mL tubes, 24-well, 48-well, 96-well and 384-well microtiter plates
Citations:
(106)
Cytek Biosciences
Cytek&#153; Northern Lights Flow Cytometery System
  • Abs / Exc:
    1-3 lasers - 405 nm: 100 mW, 488 nm: 50 mW, 640 nm: 80 mW
  • Detection:
    FSC, SSC, up to 38 fluorescent detectors
  • Throughput:
    Inquire
Citations:
(68)
Guava&#174; easyCyte&#0153; Flow Cytometers
  • Abs / Exc:
    Violet (405 nm), Blue (488 nm), Red (642 nm)
  • Detection:
    FSC, SSC, 12 fluorescent colors depending on model
  • Sample Type:
    96 Well Plates, 1.2 or 1.5 mL Tubes depending on model
  • Throughput:
    1,000 – 10,000 cells/test
Read More
Citations:
(155)
Thermo Fisher Scientific
Invitrogen&#153; Attune&#153; NxT Flow Cytometer
  • Abs / Exc:
    Blue: 488 nm (50 mW), Violet: 405 nm (50 mW), Red:637 nm (100 mW) Yellow: 561 nm (50 mW)
  • Detection:
    FSC, SSC, 14 fluorescent colors with PMTs, User changeable
  • Sample Type:
    17 x 100 mm to 8.5 x 45 mm tubes
  • Throughput:
    35,000 events per second
Read More
Citations:
(>1k)
Figures:
(4)
Invitrogen&#8482; Attune&#8482; CytPix&#8482; Flow Cytometer
  • Abs / Exc:
    405 nm, 488 nm, 561 nm, 637 nm
  • Detection:
    2 scatter channels, up to 14 fluorescence channels; Brightfield imaging capability
  • Sample Type:
    17 x 100 mm to 8.5 x 45 mm tubes
  • Throughput:
    Inquire
Citations:
(4)
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • <<
  • >>
BD Biosciences
BD Accuri C6 Plus
5
2 Figures from 379 Publications
BD Biosciences
BD FACSLyric
1
4 Figures from 163 Publications
BD Biosciences
BD LSRFortessa
4
10 Figures from 4232 Publications
BD Biosciences
BD LSRFortessa X-20
4
1 Figure from 472 Publications
Bio-Rad
12004276 / 12004277 / 12004278 / 12004279 / 12014135 / 12014136 / 12014138 / 12014139 / 12014141
6
6 Figures from 339 Publications
Miltenyi Biotec
130-196-434
7
2 Figures from 397 Publications
Miltenyi Biotec
130-096-116
2
1 Figure from 416 Publications
Thermo Fisher Scientific
Attune NxT Flow Cytometer
3
4 Figures from 1653 Publications
Showing 8 of 8 products
  • <<
  • >>