Discovery VP® Analytical HPLC System
from
Shimadzu
Description
DVP Analytical provides automated analysis, offering complete control from injection to detection to report generation and E-mail notification. All of this can be done in as little as 6 mouse clicks. As a method development tool, DVP facilitates characterization of lead candidates by utilizing multiple columns and solvent systems so the method development team, process chemistry group, and even the synthetic chemists can concentrate on new chemistry instead of struggling with separations. Powerful features like automatic instrument initialization, column flushing, and system equilibration allow around-the-clock use. Key features include: • Stacked Plot Report: Overlays chromatograms of a single sample run on up to ten columns. Options within the report allow the user to zoom in on the baseline, adjust the X and Y offsets, and add and subtract columns for the best view of the chromatograms. • Totally Automated: Eliminates the need for an operator to continually monitor the hardware and prepare the column for each injection. • Report Generation: A report can be totally customized to include a chromatogram, peak height, retention time, area, area percent, and other desired parameters. • Detection Options: The Discovery VP Analytical system is configured with a UV or PDA detector in the standard packages. Two UV wavelengths may be monitored at once, and up to 4 wavelengths isolated when a PDA is configured. Detectors such as RID or ELSD may be added. Full control of Shimadzu’s mass specs is fully integrated into DVP for easy MS operation. With DVP handling the separation, your MS will give you even better information faster.
Specifications/Features
Features:
The Stacked Plot Report overlays chromatograms of a single sample run on up to ten columns. Full automation eliminates the need for an operator to continually monitor the hardware and prepare the column for each injection. Reports can be totally customized to include a chromatogram, peak height, retention time, area, area percent, and other desired parameters. The Discovery VP Analytical system is configured with a UV or PDA detector in the standard packages. Two UV wavelengths may be monitored at once, and up to 4 wavelengths isolated when a PDA is configured. Detectors such as RID or ELSD may be added to monitor non-chromophoric compounds, and the LCMS-1010A mass spectrometer can scan or monitor positive and negative ions generated by APCI or electrospray.
Stacked Plot Report The Stacked Plot Report overlays chromatograms of a single sample run on up to ten columns. Options within the report allow the user to zoom in on the baseline, adjust the X and Y offsets, and add and subtract columns for the best view of the chromatograms.
Totally Automated Discovery VP´s full automation eliminates the need for an operator to continually monitor the hardware and prepare the column for each injection. At startup, Discovery VP can prime the pumps, and before each injection the column is flushed and equilibrated and a baseline check is done to ensure stability. When all samples are complete, Discovery VP will flush all of the columns used in the queue and turn the power off to the pumps and detector.
Report Generation Discovery VP´s Analytical report can be totally customized to include a chromatogram, peak height, retention time, area, area percent, and other desired parameters. The report is created in CLASS-VP and stored with the data acquisition method. Detection Options The Discovery VP Analytical system is configured with a UV or PDA detector in the standard packages. Two UV wavelengths may be monitored at once, and up to 4 wavelengths isolated when a PDA is configured. Detectors such as RID or ELSD may be added to monitor non-chromophoric compounds, and the LCMS-1010A mass spectrometer can scan or monitor positive and negative ions generated by APCI or electrospray.Report Generation Discovery VP´s Analytical report can be totally customized to include a chromatogram, peak height, retention time, area, area percent, and other desired parameters. The report is created in CLASS-VP and stored with the data acquisition method. Detection Options The Discovery VP Analytical system is configured with a UV or PDA detector in the standard packages. Two UV wavelengths may be monitored at once, and up to 4 wavelengths isolated when a PDA is configured. Detectors such as RID or ELSD may be added to monitor non-chromophoric compounds, and the LCMS-1010A mass spectrometer can scan or monitor positive and negative ions generated by APCI or electrospray.