Mounting Media with DAPI

Miami
MI
Student

Overall

Quality of Results

Ease-of-Optimization

What do these ratings mean?
Write a Review

Company:

Thermo Scientific

Product Name:

Prolong Gold with DAPI

Catalog Number:

P36935

This is used to mount immunostained cells onto slides. The product contains anti-fade to prolong fluorescence. It also contains DAPI, which means no pre-staining for nuclei before mounting.

Experimental Design and Results Summary

Application

Immunofluorescence

Starting Material

None

Protocol Overview

Immerse the cells on the slide in Prolong Gold. Add cover slip and let cure in a dark place. Look at cells on the microscope

Tips

It's pretty viscious so warm up with hands prior to applying

Results Summary

Prolong gold has been good for immunofluorescence with no discernible loss of fluorescence signal after looking at them for awhile. Also, the nuclei of these cells have good nuclear staining. It may not be as bright as adding dye prior to mounting but it is acceptable.

Additional Notes

None

Image Gallery

Summary

The Good

Anti-Fade with nuclear stain

The Bad

Nuclei not as bright vs staining with dye prior to mounting

The Bottom Line

This is a good product for mounting cells for downstream fluorescent experiments.