Human CD57 Antibody: Look No Further!

Overall

Quality of Results

Ease-of-Optimization

What do these ratings mean?
Write a Review
Pathology
University of Louisville
Research Associate
PE anti-human CD57 Antibody

Company:

BioLegend

Product Name:

PE anti-human CD57 Antibody

Catalog Number:

322312

Assessing the levels of CD57 on T cells is important as it has been shown to increase in diseases such as AIDS. We chose this product to examine the levels of CD57 in CD4 versus CD8 cells in healthy adult individuals.

Experimental Design and Results Summary

Applications

Flow Cytometry

Sample

Adult human peripheral blood lymphocytes

Primary Incubation

30 minutes (on ice)

Blocking Agent

1ug/ml human IgG 15 minutes

Secondary Incubation

N/A

Tertiary Incubation

N/A

Detection

FACS Calibur Flow cytometer

Results Summary

Using this antibody, we found that CD4 cells were mostly negative for CD57 while the expression on CD8 cells varies from donor to donor.The signal was good and gating was straightforward (in the attached image, the isotype control is shaded, while CD57 is the open histogram with the thick black line).

Additional Notes

None

Related Categories

Image Gallery

PE anti-human CD57 Antibody

Summary

The Good

Good signal

The Bad

No issues

The Bottom Line

A good antibody for CD57 phenotyping.

Share your experience with other scientists. Write a Review! »

Join the discussion