Welcome Guest
Login
Register
Products
Featured Products
Search Antibodies
Assay Kits
Biomolecules
All Other Products »
Articles
Editorial Articles
Product Reviews
Application Notes
News
Videos
Molecular Biology Videos
Cell Biology Videos
Lab Equipment Videos
Cell/Tissue Culture Videos
Mass Spectrometry Videos
Drug Discovery Videos
Webinars
Life Science Videos Archive
More
Events
Forums
Jobs
Promotions
Biocompare
Products
Lab Equipment
Neuroscience Equipment
Supplies
Ventilators
Ventilators (Mice)
Ventilators (Mice)
Get quotes for all products
Sort By
- select -
Item Name
Company Name
Price
Select All
Select up to 5 products from below to compare or request more information.
Request Info for all products
Compare
MiniVent Ventilator
Stoelting Co.
Catalog Number
: 50098
Description
: These newly designed ventilators are compact, quiet, lightweight and virtually vibrationless. Thus, they may be positioned directly next to the animal, eliminating tidal volume error due to system compliance. While it was designed specifially for mice, the MiniVent can be used for any animals (e.g. birds and perinatal rats) which require tidal volumes in the range of 30-350 ul. The tidal volume can be varied continuously throughout its range during operation without interrupting ventilation. The expired air can be recovered at the collection ports for sampling, recycling or generating a positive end expiratory pressure (PEEP).
Room air or any non-explosive gas mixture can be used to feed the pump intake. Larger ventilators produce large tubing and instrument dead space volumes. This introduces greater system compliance issues which can affect the accuracy with which the full tidal volume is introduced into the animal’s lungs. These ventilators reduce the tidal volume error due to system compliance to 3 ul. The MiniVent is a constant volume respiration pumps operating on the Starling principle. Unlike conventional units for larger animals, these ventilators employ a rotary plunger and have no valves. During each ventilation cycle, the plunger performs a synchronized forward and rotating movement. Cleverly arranged bores and channels in the cylinder and plunger control inspiration and expiration during each stroke of the plunger.
Each ventilator comes complete with: one AC wall mounted power supply (115 or 220V); two silicone tubings, 1.5mm I/D, 3.0 mm O/D, I4 cm length; one 1.3mm O/D tracheotomy Cannula; one 1.2 OD Intubation Cannula. This item is also available in a 220V version. For more information, including product images, technical specifications and available adaptors to allow expanded gas selection, please visit our website.
Read More
Get Quote
Supplier Page
Compare
or
Get Quote
for selected.
Ugo Basile Mouse Ventilator 0.5mL
Stoelting Co.
Catalog Number
: 50095
Description
: This new ventilator from Ugo Basile is ideal for use with mice and is also suitable for small birds and perinatal rats. A unique variable stroke linkage mechanism, very similar in principle to the one used in Basile's larger respirators, operates the piston. The reciprocating motion is adjusted and transmitted to the piston by rods and articulated joints only, which leads to minimal wear, no backlash, silent operation and exact stroke reproducibility. The stroke volume is adjustable whether the ventilator is on or off. For the most convenient and accurate stroke volume control available, the knob and scale remain stationary, even when the piston is in motion. The valve mechanism on these ventilators features nearly zero dead space and superb durability with no leakage. Expired air may be channeled for analysis and/or recycled, when used with anesthetic gases. The stroke rate (breaths per minute) is feedback controlled from 50 to 300 strokes per minute and displayed on an LED digital readout. This product is also available in a 220V model. For additional information, including product images, detailed technical information (including the product manual, dimensions, volumes, etc) and a list of articles which use this device, please visit our website.
Read More
Get Quote
Supplier Page
Compare
or
Get Quote
for selected.
Ugo Basile Mouse Ventilator 1.0mL
Stoelting Co.
Catalog Number
: 50094
Description
: This new ventilator from Ugo Basile is ideal for use with mice and is also suitable for small birds and perinatal rats. A unique variable stroke linkage mechanism, very similar in principle to the one used in Basile's larger respirators, operates the piston. The reciprocating motion is adjusted and transmitted to the piston by rods and articulated joints only, which leads to minimal wear, no backlash, silent operation and exact stroke reproducibility. The stroke volume is adjustable whether the ventilator is on or off. For the most convenient and accurate stroke volume control available, the knob and scale remain stationary, even when the piston is in motion. The valve mechanism on these ventilators features nearly zero dead space and superb durability with no leakage. Expired air may be channeled for analysis and/or recycled, when used with anesthetic gases. The stroke rate (breaths per minute) is feedback controlled from 50 to 300 strokes per minute and displayed on an LED digital readout. This product is also available in a 220V model. For additional information, including product images, detailed technical information (including the product manual, dimensions, volumes, etc) and a list of articles which use this device, please visit our website.
Read More
Get Quote
Supplier Page
Compare
or
Get Quote
for selected.
Ugo Basile Rodent Ventilator 5mL
Stoelting Co.
Catalog Number
: 50095-2
Description
: This "quality-first" line of animal ventilators from Basile is in every detail superior to competitive instruments. Their unique design ensures accuracy, durability and quietness of operation unequalled by any other ventilator. The valve mechanism on these ventilators features nearly zero dead space and superb durability with no leakage. Expired air may be channeled for analysis and/or recycled, when used with anesthetic gases. The stroke rate is displayed on an LED readout. These ventilators are the most accurate and reliable available, due to feedback controlled motor speed. The stroke volume is adjustable whether the ventilator is on or off. For the most convenient and accurate stroke volume control available, the knob and scale remain stationary, even when the piston is in motion. Other advantages of this unique mechanism are the elimination of mechanical noise, reduced wear, and very low maintenance requirements. Rat and mouse units are supplied with one of two easily interchangeable cylinder/piston assemblies that enable a broader range of stroke volumes. Additional cylanders are available on our website. A 220V model is also available on our website. For additional information, including images, detailed technical specifications and a list of articles that use Ugo Basile ventilators, please visit our website.
Read More
Get Quote
Supplier Page
Compare
or
Get Quote
for selected.
Select All
Select up to 5 products from above to compare or request more information.
Request Info for all products
Compare
Tags:
Please Login or Register to Create Tags
Feedback
Company Filter
Help
Use this product listing in multiple ways:
Click
Get Quote
to receive a quote from the vendor for that product
Check up to 5 products and click to
compare
to view product specifications side by side or
Get quote
to get a quote for all your selected products
Click
Get quotes for all products
at the top of the list to get a quote for all products
Vendor Filter
Stoelting Co.
Reviews
Luciferase Assay System by Promega
Mouse IL-1beta ELISA MAX Standard by BioLegend
Pyruvate Assay Kit from Biovision Inc.
Webinars and Videos
nScope eMRI
Web Seminar: Targeted Sequencing in Tumor Samples Streaming Video
Watch video: Philisa® Thermal Cycler Streaming Video
Editorial Articles
In Vitro Kinase Assays: Radiometric Measurements and Their Alternatives
Spectrophotometers: Finding Your Home in the Range (of Wavelengths)
Key Features in the Latest Flow Cytometry Systems